Replacing a faulty mpm/mpm+/mpmx card, Removing the mpm/mpm+/mpmx card from the mcu, Replacing a faulty mpm/mpm+/mpmx card -35 – Polycom DOC2558A User Manual

Page 41

Advertising
background image

Polycom RMX 2000 Hardware Guide

1-35

Replacing a Faulty MPM/MPM+/MPMx Card

Removing the MPM/MPM+/MPMx Card from the MCU

All MPM/MPM+/MPMx cards can be installed or removed while the

RMX 2000 is powered on and operating.
Prior to removing an MPM/MPM+/MPMx card the captive screws must

be unscrewed and the ejector levers must be opened to initiate a “power

down” on the card.
1

If applicable, loosen the captive screws and remove the slot cover.

2

Power down the card by partially opening the ejector levers until the
blue HS LED on the card and the Control Unit start to flash.

3

The power off sequence for the interconnected MPM/MPM+/MPMx

and RTM ISDN cards are initiated as follows:

—

All participant connections on the card are disconnected.

—

A fault is generated on the system.

—

For each disconnected participant, a participant disconnection

event is written to the CDR with the disconnection cause

Disconnected by Operator.

—

New participant connections are blocked when the card is

removed.

—

If an RTM ISDN card is connected to the MPM/MPM+/MPMx

card it is also powered off and all ISDN and PSTN participants

are disconnected.

—

When an RTM ISDN card is removed, its resources are deducted

from the Resource Report.

—

A Log File entry is written indicating MPM/MPM+/MPMx card

removal.

—

Port usage is re-calculated and the Port Gauges and Video/Voice

Port Configuration dialog box are updated.

4

When the blue HS LEDs on the MPM/MPM+/MPMx, RTM ISDN

and Control Unit stop flashing and remain lit, unscrew the captive

screws and move the ejector levers to their fully open position and

remove the MPM/MPM+ card.

Warning!
Once the removal sequence is initiated the process cannot be terminated and
the HS LED flashes.

Advertising