Chapter 5 DIP SWITCH
There is a DIP switch for the setting on converter mode of
copper and fiber port. Refer to the table below for more details.
FT-1105A
Switch 1
On
2-Port Redundant (TP)
Off
3-Port Switch (default)
Switch 2
On
LBR ON
Off
LBR OFF (default)
2-Port Redundant (FT-1105A)
When TP Redundancy is enabled, TP Port-2 and TP Port-3 are
configured as either forwarding or disabled. At any given time,
one port will be disabled and one port will be forwarding.
3-Port Switch
When TP Redundancy is disabled, all ports (Port-1, Port-2 and
Port-3) act as normal bridging ports.
LBR (Loop Back Reply)
Enable/Disable the converter to reply for Loop Back Test.