15

LED and Beeper Indications

The Base Station LED indicators and the scanner’s LEDs and beeper
are used to announce system status and perform other useful signals.
The tables below list the default function of each of the various indi-
cators.

Table 1. Scanner GREEN LED Functions

NOTE

Some LED and beeper indications can be disabled
or modified via scanner programming. The tables
indicate the default behavior of the indicators, with
shaded rows representing features that are pro-
grammable.

LED

INDICATION

DURATION

COMMENT

Disable
Indication

100ms on, 900 ms off

Indicates the scanner
has been disabled.

Good Read
Indication

500 ms on

Indicates a bar code
has been read and
decoded.

Program
Mode
Indication

500 ms on, 500 ms off
Continuous flashing

Indicates the scanner
is in Programming
Mode.

Field
Replaceable
Unit (FRU)
Indications

Varies. Consists of a
long flash followed by
multiple short flashes.

Enables service tech-
nicians to identify
Field Replaceable Unit
(FRU) errors.

Low Battery
Indication

Two flashes at 100 ms
on, 350 ms off.

Occurs at trigger pull
before the laser is
enabled. Indicates the
battery is in need of
recharging.