Configuring the e1 ports – Paradyne ENE2020-P User Manual
Page 5
5
Configuring the E1 Ports
Configuration Switches for both E1 Port 1 and E1 Port 2 are numbered from left to right,
1–8.
Table 1. Configuration Switch Settings
ENE2020-P Provider
Configuration Switches
ENE2020-S Subscriber
Configuration Switches
Switch Port 1
Port 2
Port 1
Port 2
1
Speed
Speed
Not used. The ENE2020-S
determines speed via
communication with its partner E1
provider unit.
2
3
Frame Type
Not used. Port 2
frame type is
determined by
the Port 1 frame
type
configuration.
Frame Type
Not used. Port 2
frame type is
determined by
the Port 1 frame
type
configuration.
4
Line Code
Not used. Port 2
line code is
determined by
the Port 1 line
code
configuration.
Line Code
Not used. Port 2
line code is
determined by
the Port 1 line
code
configuration.
5
Not used
Not used
Not used
Not used
6
Not used
Not used
Not used
Not used
7
Timing
Not used. Port 2
timing is
determined by
the Port 1 timing
configuration.
Not used. The ENE2020-S
determines timing via
communication with its partner E1
provider unit
8
Not used
Not used
Not used
Not used