51.Running Sense

Function
External control apparatus grasps the power supply state of a plasma monitor.
A plasma monitor is made to recognize connection of PC CONTROL.
Transmission Data

1FH 80H 60H 88H 00H CKS

ACK

7FH 60H 80H 88H 01H DATA CKS

DATA: Bit0:Connect Condition

0: No connection

1: Connected

Bit1 0: Fixed

1:-

Bit2:Power Status

0:POWER ON

1:POWER OFF(STANBY)

Bit3 0: Fixed
Bit4 0: Fixed
Bit5 0: Fixed
Bit6 0: Fixed
Bit7 0: Fixed