Table 3-1. default configuration for fault alarm – Hamilton Sundstrand Company ACT2000 User Manual

Page 47

Advertising
background image

Fault Type

Low

Alarm

High

Alarm

Fault

Enable

Persist

Time

Auto

Reset

Output

Driver Overcurrent

N/A

1000 lbf

Yes

10 Secs

Yes

Yes

Tracking Error

N/A

3.33 %

Yes

10 Secs

Yes

Yes

Position Demand

3.5 mA

20.5 mA

No

1 Sec

No

No

RDC

Failure N/A N/A Yes N/A No

Yes

+14 Volts

12.0 Volts

16.0 Volts

Yes

7.5 Secs

Yes

Yes

–14 Volts

–16.0 Volts

–12.0 Volts

Yes

7.5 Secs

Yes

Yes

Input Voltage

75.0 Volts

180.0 Volts

Yes

7.5 Secs

Yes

Yes

EEPROM

Checksum

N/A N/A Yes N/A No

Yes

Motor High Temp

N/A

130° C

No

10 Secs

No

No

Electronics High Temp

N/A

110° C

Yes

10 Secs

Yes

Yes

+5 Volts

4.5 Volts

5.5 Volts

Yes

7.5 Secs

Yes

Yes

Watchdog

Expired N/A N/A Yes N/A No

Yes

EEPROM

Write N/A N/A Yes N/A No

Yes

Table 3-1. Default Configuration For FAULT Alarm

Fault Type

Low

Alarm

High

Alarm

Fault

Enable

Persist

Time

Shut-

Down

Output

Driver Overcurrent

N/A

1000 lbf

No

10 Secs

No

No

Tracking Error

N/A

3.33 %

No

10 Secs

No

No

Position Demand

2 mA

22 mA

No

1 Sec

No

No

RDC

Failure N/A N/A No N/A No

No

+14 Volts

12.0 Volts

16.0 Volts No 7.5

Secs No No

–14 Volts

–16.0 Volts

–12.0 Volts No 7.5

Secs No No

Input Voltage

75.0 Volts

180.0 Volts

No

7.5 Secs

No

No

EEPROM Checksum

N/A

N/A

No

7.5 Secs

No

No

Motor High Temp

N/A

135° C

Yes

10 Secs

Yes

Yes

Electronics High Temp

N/A

110° C

No

10 Secs

No

No

+5 Volts

4.0 Volts

6.0 Volts

No

7.5 Secs

No

No

Watchdog

Expired N/A N/A No N/A No

No

EEPROM

Write N/A N/A No N/A No

No

Table 3-2. Default Configuration For OVERTEMP Alarm

CH. 3: OPERATING THE ACT2000

41