Power – Panasonic CS-A12CKPG User Manual

Page 7

Advertising
background image

ENGLISH

6

Operation Details

COOL – Cooling Operation

To set the room temperature at your preference
cooling comfort.

AUTO – Automatic Operation

Sense indoor temperature to select the optimum
mode.

Temperature is not displayed on the remote control
during AUTO operation.

DRY – Soft Dry Operation

A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.

During Soft Dry operation, the indoor fan operates at
Low fan speed.

HEAT – Heating Operation
(for Heat Pump Model only)

Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced.

Defrosting Operation
Depending on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.

FAN – Air Circulation Operation
(for Cooling Model only)

When the room temperature reaches the set
temperature, operation commences at Low airflow
volume. It stops when the room temperature drops to
4°F below the set temperature.
(It is useful when using a heater).

Hi fan speed will not operate when using the air
circulation Fan mode.

Setting the Horizontal Airflow Direction

• Adjust it manually

Notes

If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.5 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.

If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.

POWER

POWER

TIMER

TIMER

QUIET

QUIET

POWERFUL

POWERFUL

POWERFUL

POWERFUL

ECONOMY

ECONOMY

ECONOMY

ECONOMY

POWER

POWER

TIMER

TIMER

QUIET

QUIET

MANUAL
Five stages of adjustment
can be made between
14 ~ 36 angle.

MANUAL
Five stages of adjustment
can be made between
0 ~ 61 angle.

Heat Pump Model

MANUAL
Five stages of adjustment
can be made between
14 ~ 36 angle.

MANUAL
Five stages of adjustment
can be made between
0 ~ 61 angle.

– When the discharge air

temperature is low such
as at the start of heating
operation, the air blows
in a horizontal direction.
As the temperature
rises, the hot air blows
in a downward direction.

– To stop this operation,

press MANUAL.

HEAT Operation

AUTO

COOL / DRY Operation

AUTO

Swing up/down
Automatically

36°

Swing up/down
Automatically

Move up/down
Automatically

36°

61°

COOL / DRY Operation

AUTO

FAN Operation

AUTO

Setting the Fan Speed

• Press 4 to select:-

FAN

– Low Fan Speed

FAN

– Medium Fan Speed

FAN

– High Fan Speed

AUTO
FAN

Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.

Setting the Vertical Airflow Direction

• Press 5 or 6 to select:-

Cooling Model

Use this air conditioner under the following

conditions:

Heat Pump Model

DBT: Dry Bulb Temp
WBT: Wet Bulb Temp

Maximum Temperature

Minimum Temperature

WBT

73.4

51.8

DBT

109.4

60.8

WBT

78.8

51.8

Indoor

Outdoor

(Unit in °F)

DBT

89.6

60.8

DBT: Dry Bulb Temp
WBT: Wet Bulb Temp

Maximum Temperature-Cooling
(Maximum Temperature-Heating)

Minimum Temperature-Cooling
(Minimum Temperature-Heating)

DBT

89.6

(86)

60.8

(60.8)

WBT

73.4

(–)

51.8

(–)

DBT

109.4

(75.2)

60.8

(23)

WBT

78.8

(64.4)

51.8

(21.2)

Indoor

Outdoor

(Unit in °F)

Cooling Model