8

■ Pre-season Inspection

● Is the discharged air cold/warm?

Operation is normal if 15 minutes after the start of
operation, the difference between the air intake and
outlet vents temperature is:-

● Are the air intake or outlet vents of the indoor or

outdoor units obstructed?

● Are the remote control batteries weak?

If the remote control display appears weak, replace
the batteries.

■ When the Air Conditioner is Not Used

for an Extended Period of Time

1

To dry the internal parts of the indoor unit, operate
the unit for 2 - 3 hours using:-

2

Stop the operation by remote control and switch off
the circuit breaker.
Note : If the unit is not switched off by the remote
control, it will start operating when the circuit
breaker is switched to ON. (The unit is equipped
with Auto Restart Control.)

3

Remove the remote control batteries.

■ Recommended Inspection

• After used over several seasons, the unit will

become dirty and thus decreases the unit’s
performance. Depending on the operation
conditions, a dirty unit may produce odor and dust
may pollute dehumidification system. Therefore, a
seasonal inspection is recommended in addition to
regular cleaning. (Consult an authorized dealer.)

CARE AND MAINTENANCE

■ Cleaning the Indoor Unit and Remote

Control

• Wipe gently with a soft, dry cloth.
• Do not use water hotter than 104˚F or polishing fluid

to clean the unit.

■ Cleaning the Air Filter

(Recommendation:- If the unit is operated in a dusty
environment, clean the filters every two weeks.
Continuous use of this dirty filters will reduce cooling
or heating efficiency)

1

Remove dirt using a vacuum cleaner.

2

Wash back of the air filter with water.

3

If badly soiled, wash it with soap or a mild household
detergent.

4

Let it dry and reinstall it.
Be sure the “FRONT” mark is facing you.

* Damaged air filter.

Consult the nearest authorized dealer.
Part No.: CWD001098.

• Do not use benzene, thinner, scouring powder or

clothes soaked in caustic chemical to clean the unit.

■ Cleaning the Front Panel

(Must be removed before washing)

1

Raise the front panel higher than the horizontal and
pull to remove it.

2

Gently wash with water and a sponge.
• Do not press the front panel too hard when washing.
• When use kitchen cleaning fluid (neutral detergent),

rinse throughly.

• Do not dry the front panel under direct sunlight.

3

To affix the front panel, raise the front panel
horizontally, match the protruding portion on the
indoor unit to the fulcrum and push into place.

■ Air Purifying Filters

● Solar Refreshing Deodorizing Filter

• Used to remove unpleasant odor and deodorize

the air in the room.

• Reusable.
• Vacuum, place under direct sunlight for 6 hours and

fit it back in place.
(Recommended: every 6 months)

• Recommended to change this filter every 3 years.

● Air Purifying Filter

• This new filter helps trap small airborne particles

such as dust, pollen and tobacco smoke.

• Recommended : change this filter every 3 months.

•

Do not reuse damaged filters.
Consult the nearest authorized dealer to purchase a
new filter.
Air Purifying Filter No.: CZ-SF51P
Solar Refreshing Deodorizing Filter No.: CZ-SFD70P

•

If you operate the air conditioner with dirty filters:-
– Air is not purified
– Cooling or heating capacity decreases
– Foul odor is emitted

Fulcrum

Protruding portion on indoor unit

2

Remove the air filters

1

Raise the
front panel

Air Purifying Filter

Solar Refreshing
Deodorizing Filter

Heat Pump Model

COOL –> 14°F or above
HEAT –> 25°F or above

Cooling Model

COOL –> 14°F or above

Heat Pump Model

COOL operation with 86°F
set temperature

Cooling Model

FAN operation