Handle features – Porter-Cable 741 User Manual

Page 10

Advertising
background image

10

3, counterclockwise (as viewed from the front of the saw).

4. Insert the blade into the clamp until it bottoms. Allow the release collar to

rotate clockwise to lock the blade in place, (A) Fig. 4.

5. To remove blade: repeat steps 1 through 3, and pull blade from blade

clamp (while the release collar is being held in the open position).

NEVER TOUCH BLADE IMMEDIATELY AFTER USE, AS IT MAY

BE EXTREMELY HOT.

NOTES: If the blade clamp collar resists rotation to remove a blade,

work the blade up and down while rotating the clamp (in a counter-

clockwise direction).
If the blade breaks leaving nothing to grasp (to pull it from the

clamp), it may be necessary to

use another blade as a tool to aid

in removing the broken piece (see

Fig. 5). While holding the release

collar in the open position, use

the tip of another blade to “hook”

the broken piece and pull it from

the clamp. (A thin, fine-toothed,

metal-cutting blade works best.)
Periodically clean the blade

clamp with dry compressed

air. DO NOT lubricate the blade

clamp. Lubricant can attract contamination.

WEAR ANSI Z87.1 SAFETY GLASSES WHILE USING

COMPRESSED AIR.

HANDLE FEATURES

The

Model 741 is supplied with a soft grip handle.

FLUSH

RECESSED

BREAK

BREAK

BROKEN

BLADE

BROKEN

BLADE

Fig. 3

A

Fig. 5

Fig. 4

A

Advertising