5d - maintenance and servicing, Cautions – Panasonic MC-CG461 User Manual

Page 5

Advertising
background image

5

D - MAINTENANCE AND SERVICING

Indicator for replacing the dust bag

Turn the power control to the highest setting and lift the nozzle

off the floor. If the dust indicator turns red, the dust bag is full

and requires replace the dust bag.

NOTE: If the dust bag is not properly installed, the cover will

not close. Be sure to check that the bag is properly

installed before operating, otherwise dust will leak out.

The dust bag can easily lay on the dust cover packing or

clip between bag collar and body, so be sure to properly

extend it into the vacuum cleaner body.

Replacing the dust bag

D-1 Lift dust cover catch and raise dust cover until it

clicks properly.

D-2 Remove bag collar from bag holder and pull out dust

bag.

D-3 Set the dust bag.

D-4 Close dust cover.

D-5 When using a cloth bag

Slide the bag clip to open the dust bag, pour out the dirt,

then slide the bag clip back to its original position.

(Please don’t throw away the bag clip.)

Next slide the cardboard back inside the bag frame slot,

and cover with the dust cover.

Floor nozzle

D-6 Inspect once a month.

Using an old toothbrush or similar tool, clean any dirt or

lint from the brush.

Ionizer nozzle

D-7

(1) Insert key or other object into the screw slot and turn

it to the left to move “ ” to the ▲ position and roll

down the brush cover ring.

(2) Take out the return brush.

(3) Remove the dirt attached to the return brush.

(4) Assemble the return brush according to the

original.

(5) Move the top of the brush cover from “ ” to ▲

position. Then insert a key or other object into the

screw slot and turn to the right to move “ ” to the

▲ position.

Turbine nozzle

D-8 After removing the brush cover with a coin, remove the

beater bar from the belt.

Then cut across threads, strings, hairs, etc. from the

beater bar with a pair of scissors. (Removal as per

reverse procedure)

NOTE: Take care not to cut the brush.

Do not wash in water.

Vacuum cleaner body

D-9 Wipe with a soft cloth soaked with water.

CAUTIONS

• The plug must be removed from the socket-outlet

before cleaning or maintaining the appliance.

• To avoid injury, keep your fingers and hands away

from the beater bar.

• DO NOT use hot air or hot surface to dry filters. Keep

at room temperature for approximately 24 hours.

• IMPORTANT: Before re-installing the washable filters,

make sure they are completely dry to avoid damaging

the cleaner.

Maintaining the Pre-motor Filter

Perform the procedure given below when the suction power is

not restored after maintaining the filter.

D-10 Open the dust cover.

D-11 Remove the pre-motor filter.

D-12 Wash gently with water and then allow to dry in a

shaded location.

D-13 Replace to its original location.

NOTE: Make sure you remember to replace the filter. If the filter

is not installed, it will cause motor failure.

• Do not wash the filter in a washing machine or dry it with a

dryer or other source of hot air.

Filter care

D-14 Exhaust filter

Exhaust filter, is installed in the rear side of the vacuum

cleaner. This filter retains any small dust particles which

may be present in the expelled air.

lt is advisable to change the clean air filter once or twice

a year, depending on use. To change the filter, hold the

exhaust cover (as illustrated). After changed the filter,

set the exhaust cover to its position (as illustrated).

NOTE:

IMPORTANT: Never use the cleaner without the correct filters

properly installed. Failure to do so may result in

damage to the motor.

What to do if your cleaner does not work

Check that the appliance is correctly plugged in and that the

electrical socket is working. In case that the thermal cut-out

device has operated, wait until it resets after approximately

60 minutes. If after having checked the mentioned points, the

cleaner does not work, take it to an Authorised Service Centre to

be repaired.

What to do when the suction performance

reduces

• Stop the cleaner and unplug from the socket.

• Check whether the wands, hose and accessories are blocked or

not. If they are blocked, remove the obstruction.

• Check that the dust compartment is full. If it is full, empty it.

• Check that Pre-motor Filter or Exhaust Filter is blocked with

dust. If they are blocked, clean them out or replace.

SPECIFICATIONS

MC-CG467

MC-CG465

MC-CG463 MC-CG461

Max. Input

1800 W

1500 W

Nominal input

1500 W

1300 W

Dimensions
(W x L x H)

280 mm x 425 mm x 260 mm

Net weight

4.5 kg

Extension wands

Telescopic

Metal x2/

Telescopic

Crevice nozzle

Dusting brush

Floor nozzle

Turbine nozzle Ionizer nozzle

Floor nozzle

REMINDER FOR CUSTOMER
The model and serial number of this product may be found on the

nameplate located at the underside of your cleaner. You should

note the model and serial number in the spaces provided and

retain this book as a permanent record of your purchase.

Model Number. .............................................................................

Serial No. ......................................................................................

Date Purchased. ...........................................................................

Where Purchased. ........................................................................