Pelco CM6700 User Manual

Page 24

Advertising
background image

24

Pelco Manual C523M-H (6/05)

Table B. Programming the CM6700 Switching Control Unit (Continued)

Step

4

Function

Action

Result

a. Enter the Main Menu.

b. Press 2.

c. Enter the desired monitor number (01-04) or pan left/

right to show the desired monitor number.

d. Move down to highlight the ALARM TYPE: field.

e. Use the F1 and F2 keys to find the desired alarm

type.

f. Move down to highlight the ALARM DWELL field.

g. Use the keypad to enter the desired dwell time

(1 to 99 seconds).

h. Move down to highlight the DISPLAY field.

i. Use F1 and F2 to toggle the character display on or

off.

j. Move down to the 1. CAMERA SEQUENCE field.

k. Pan right.

l. Use the position keys or joystick to move around the

menu. Set Camera Number (1-16), Dwell Time (1-99
sec.) and Preset number for each camera in the
sequence. Enter zeroes to skip a camera.

m. Move down to RETURN.

n. Pan right.

Program
Monitors

Alarm Type:
Manual – must
press ACK to reset.
Auto – alarm resets
10 seconds after
alarm normalizes.
Off – no alarms
shown.

Alarm Dwell:
1 to 99 seconds –
time between
display of multiple
alarm screens.

Character Display:
On or off.

Program Camera
Sequences:
Each monitor can
have one 16-step
sequence. Set dwell
time and preset
number for each
camera.

The Main Menu appears.

The Monitor NN screen appears. NN is the monitor
number. The monitor number flashes.

The selected number appears on screen.

The current alarm type for the selected monitor
appears on screen.

The selected alarm type appears.

The current alarm dwell for the selected monitor
appears on screen.

The entered dwell time appears.

The current status of character display appears.

Asterisk (*) = on, dashes (--) = off.

The 1. In the 1. CAMERA SEQUENCE field flashes.

The Monitor NN Sequence Menu appears.

The entered values appear.

The R in RETURN flashes.

The Monitor NN screen appears.

ACK

Enter Monitor # (1-4).

Select Alarm Type

(Off, Auto, Manual).

Set Alarm Dwell

(0-99 sec).

Turn display On/Off.

Keypad

F1/F2

Keypad

F1/F2

Enter Monitor #.

Set Dwell time (1-99 sec)
and Preset number
for each camera
in the 16-step sequence.

Enter Monitor #.

Turn each alarm on/off
(*/--).

Move text around on the
screen to place it in the
desired location.

Press ACK when done.

Keypad

Keypad

Keypad

F1/F2

Pan/Tilt

PROCEDURE METHOD

PROCEDURE METHOD

PROCEDURE METHOD

PROCEDURE METHOD

ALM SET ALM SET ALM SET

RETURN

ALARM DWELL: 05
DISPLAY: *
1. CAMERA SEQUENCE
2. ALARM ENABLE
3. POSITION DISPLAY

MONITOR XX

ALARM TYPE: AUTO

RETURN

MONITOR XX

ALARM ENABLE

ENTRY 1-8 ENTRY 9-16

01 02 00
02 02 00
03 02 00
04 02 00
05 02 00
06 02 00
07 02 00
08 02 00

09 02 00
10 02 00
11 02 00
12 02 00
13 02 00
14 02 00
15 02 00
16 02 00

CAM DWL PRE CAM DWL PRE

1 -- 7 -- 13 --
2 -- 8 -- 14 --
3 -- 9 -- 15 --
4 -- 10 -- 16 --
5 -- 11 -- 17 --
6 -- 12 -- 18 --

DISPLAY

SHOWING

POSITION

OF TEXT

MONITOR XX

SEQUENCE MENU

(Continued on next page)