SYSTEM CONNECTION

1. Single Monitor Connection

2. Multiple Monitor Connection

Internal Sync Connection

• Connect the Video Input Connector (11) on the

monitor to the Video Out Terminal of cameras with

75-ohm coaxial cables.

External Sync Connection

• When a non-composite video signal is connected

to the video monitor, it must also have an external

composite SYNC signal connected to the video

monitor.

• Set the Sync Selector Switch (13) at EXT position.

• Loop through connection of sync signal is the

same as the case of Video Signal.

120V
AC
60 Hz

120V
AC
60 Hz

120V
AC
60 Hz

Last Video Monitor

Camera

Camera

Coax. Cable

WV-BM500

WV-BM500

Coax.
Cable

Coax.
Cable