PATTON MODEL 1180/35 SPECIFICATIONS

Transmission Format:

Synchronous

Range:

1.5 miles at all data rates, 3 miles at
specified data rates

Data rates:

2.4, 9.6, 14.4, 19.2, 28.8, 48, 38.4, 56,
64,128, 144, 192 and 256 Kbps

Interface:

ITU/CCITT V.35 (M/34 female)

Transmit Mode:

Single 62.5 or 50 µ core, multi-mode fiber
cable

Clocking:

Internal, external or received recovered

Handshaking:

Software (X-ON/X-OFF) or hardware
(RTS/CTS), both modes available at all
times

Application:

Point-to-point

Typical Link Budget:

8 dB with a 50 µ cable; 12 dB with a
62.5 µ cable

Responsivity Minimum: 0.12 A/w

LED Indicators:

TD, RD, RTS, CTS, power, test

Diagnostics:

Local and remote loopback

Fiber Connector:

ST or SMA

DTE Connector:

M/34 female

Dimensions:

4.127"w x 1.52"h x 5.0"l

Power Supply:

Wall-mount, 7.5VDC

14

SYMPTOM

PROBLEM

SOLUTION

Data passes, but
hardware flow
control doesn't
work

1180/35s work in
async. mode, but
not sync. mode

1. Incorrect DIP switch
setting

1. Incorrect DIP switch
setting

1. Switch 7 must be in
the ON condition for
hardware flow control
signals to pass
between 1180/35s;
both units must be set
the same way

1. Switch 8 (internal/
external clock) must
be set the same way
for both 1180/35s