3

3.0 INSTALLATION

Patton's Model 571 and 581 surge protectors are easy to install

and are designed to operate transparently to your network. This
section describes connection procedures for both models.

3.1 PRODUCT APPLICATIONS

Both Models 571 and 581 protect 4 pins on the modular RJ-45 Cat-

5 interface, and work in environments with data rates up to 100 Mbps.
The following descriptions will give you a general guideline for installing
the units in your Cat-5 environment.

3.1.1 POINT-OF-USE APPLICATION (MODEL 571)

The Model 571 is designed for installation on LAN equipment in a

typical office environment (see Figure 1, below). For best results the
Model 571 should be connected as close as possible to the
communication port of the device to be protected . Also, the flat
braided grounding wire on the Model 571 should be attached to the
grounded metal frame of the device being protected.

Figure 1. A typical Point-of-Use Application for the Patton Model 571.

Model 571

Model 571

1 (TX +)
2 (TX -)
3 (RX+)
4 (N/C)
5 (N/C)
6 (RX-)
7 (N/C)
8 (N/C)

1
2
3
4
5
6
7
8

APPENDIX B (Continued)

EIA/TIA TSB-40A COMPLIANCE

TSB-40A COMPLIANCE TESTING RESULTS

TYPICAL NEAR-END CROSSTALK MEASUREMENT