Philips Magnetoresistive Sensor User Manual

Page 26

Advertising
background image

2000 Sep 06

26

Philips Semiconductors

Magnetoresistive sensors for
magnetic field measurement

General

S

ENSOR TEMPERATURE DRIFT

The sensitivity of MR sensors is also temperature
dependent, with sensitivity decreasing as temperature
increases (Fig.31).The effect on sensor output is certainly

not negligible, as it can produce a difference of a factor of
three within a

25

°

C to +125

°

C temperature range, for

fields up to 0.5 kA/m. This effect is not compensated for by
the flipping action described in the last section.

Fig.31 Output voltage ‘V

o

’ as a fraction of the supply voltage for a KMZ10B sensor, as a function of transverse

field ‘H

y

’, at several temperatures.

handbook, full pagewidth

3

0

15

3

2

2

MLC134

5

10

10

5

15

0

1

1

H (kA/m)

y

VO

(mV/V)

T = 25 C

amb

o

25 C

o

75 C

o

125 C

o

operating range