Appendix A Safety Requirements

9/12

APPENDIX A SAFETY REQUIREMENTS

•

Any tester, equipment, or tool used at any production step, or for any

manipulation of semiconductor devices, have its shield connected to ground.

•

The product must be placed on a conductive table top, made of steel or clean

aluminum, or covered by an antistatic surface (superficial resistivity equal to or

higher than 0.5 M

Ω/cm

2

), grounded through a ground cable (conductive cable

from protected equipment to ground isolated with a 1 M

Ω resistor placed in

series). All manipulation of finished goods must be done at such a grounded

worktable.

•

The worktable free of all non-antistatic plastic objects.

•

An antistatic floor covering grounded through a conductive ground cable (with

serial resistor between 0.9 and 1.5 M

Ω) should be used.

•

It is recommended that you wear an antistatic wrist or ankle strap, connected to

the antistatic floor covering or to the grounded equipment.

•

If no antistatic wrist or ankle strap is worn, before each manipulation of the

powered-on tool, you touch the surface of the grounded worktable.

•

It is recommended that antistatic gloves or finger coats be worn.

•

It is recommended that nylon clothing be avoided while performing any

manipulation of parts.