Napco Security Technologies Signature 5500 User Manual

Page 2

Advertising
background image

‘‘1’’ in two consecutive locations.

TAMPER

TAMPER

If the cover is removed, the keypad sounder will pulse and

the display will indicate a zone-module tamper condition

along with the module number. Press [

RESET

] to silence the

sounder.

LOOP RESPONSE

LOOP RESPONSE

Loop response times for Zones 1 through 8 are pro-

grammed in the control panel. Normal loop response for

all expansion zones is 750mS. To reduce the response time

of an expansion zone to 50mS, cut the respective resistor

at the upper-left corner of the board. Refer to the Wiring

Diagram.

STATUS LED

STATUS LED

The Status LED displays the condition of the zone mod-

ule. The LED will blink every few seconds to indicate that

each 4-zone group is operating normally. The LED in the

4-zone module will blink once; the LED in the 8-zone

module will blink once for the first group, then double-blink

shortly thereafter for the second. See TROUBLESHOOT-

ING for other indications.

PGM TERMINAL

PGM TERMINAL

The PGM terminal (Terminal 6) will go low when the area

is armed. This terminal may be used to light an LED or trip

auxiliary equipment. Note:

Note: This terminal is programmed in

the control panel; it may be selected to trip when any one

area is armed (not necessarily its own). Refer to the instal-

lation instructions for the control panel for programmable

options.

4Z/8Z ZONE JUMPER

4Z/8Z ZONE JUMPER

To convert an 8-zone module for use with only 4-zones,

remove the jumper just below the large microprocessor IC

on the circuit board.

TROUBLESHOOTING

TROUBLESHOOTING

A steady Status LED is most likely caused by loss of

data reception from the control panel at the module’s

Terminal 3.

No illumination is most likely due to a loss of power at

Terminals 1 and/or 2.

WIRING DIAGRAMS

WIRING DIAGRAMS

Zone Wiring Diagram.

Zone Wiring Diagram.

22

Advertising
This manual is related to the following products: