11600205211REVA

INSPECTION:

Carefully unpack and inspect your HSC 585-MULTI for shipping damage. Each machine is tested

and inspected before shipping. Any shipping damage incurred is the responsibility of the carrier.

You should notify the carrier immediately if you notice damage to the box or to the machine or

parts.

CLEANING SOLUTIONS:

Select a proper pre-spray for the surface to be cleaned, and apply the pre-spray. Use a neutral

pH rinse or detergent (6 to 9 pH) in the HSC 585 to prevent premature wear of the pump, seals

and other components. Powdered chemicals are not recommended.

MAINTENANCE:

For optimum performance, flush the machine with clear water at the end of each working day.

Once a month, minimum, run a flushing compound through the machine to break up any

mineral or chemical build-up that may have formed in the lines, the pumps, or the heater.

The vacuum motor, pump motor, and the pump do not require any scheduled maintenance;

however, the vacuum motors may require replacement brushes after 1000 - 1500 hours, and the

high pressure pump and unloader valve may require rebuild kits after 500 -1000 hours (refer to

machine part list for numbers). Clean the body with an all purpose detergent, and protect it with

an automobile interior polish. Lubricate the wheels, castors, and quick disconnects with an all-

purpose silicone spray.

Record the serial number and model of your new extractor here:

Model: HSC 585-Multi_ Serial Number: __________________

Purchase Date:_____________

Write the name and phone number of your distributor:

_____________________________________

_____________________________________

NOTE: to remove the complete reel with hoses from the machine, pull the vacuum hose loose
from the hose barb on the front of the tank, and push the short piece of vacuum hose into the
center of the hose spool. Disconnect the solution hose quick coupling. Grasp the spool from either
side, and lift it off the machine.

NOTE: before servicing any component in the base cabinet, remove the hoses and spool before
opening the tanks.