B.

MOUNTING THE LINKS 2 ASSEMBLY

(1)

Refer to Figure 2 for the mounting location of the Nortec LINKS 2 Bracket on the
GS or SE unit. If pilot holes for the mounting screws are not already present on the
humidifier frame follow steps 2 and 3. If pilot holes are present then disregard
steps 2 and 3.

(2)

Using the bracket assembly as a template, mark locations of pilot holes on the
GS/SE humidifier frame.

(3)

Using 1/8” drill bit, drill pilot holes for the bracket mounting screws.

(4)

Install the bracket assembly using 8-32x ½” hex-drive screws. Be sure to route the
power wires for the I/O Controller-E module through the cutout on the upper right-
hand corner of the bracket, as illustrated in the following figure. After running wires
behind bracket, route the power leads into the main wire track.











Figure 2. LINKS 2 Bracket Placement

Screw