Technical Data KM 183 / KM 184 / KM 185

Acoustical operating principle ..... Pressure/Pressure gradient transducer
Directional pattern .............................. omnidirectional/cardioid/hypercardioid
Frequency range .................................................................................... 20 Hz...20 kHz
Sensitivity at 1 kHz into 1 kohm ............................................. 12/15/10 mV/Pa
Rated impedance .................................................................................................. 50 ohms
Rated load impedance ................................................................................. 1000 ohms
Signal-to-noise ratio, CCIR

1)

(rel. 94 dB SPL) ............................ 70/72/70 dB

Signal-to-noise ratio, A-weighted

1)

(rel. 94 dB SPL) .............. 81/81/79 dB

Equivalent noise level, CCIR

1)

............................................................... 24/22/24 dB

Equivalent noise level, A-weighted

1)

............................................ 13/13/15 dB-A

Maximum SPL for THD 0.5%

2)

................................................ 140/138/142 dB

Maximum output voltage ..................................................................................... 10 dBu
Supply voltage (P48, IEC 61938) ......................................................... 48 V ± 4 V
Current consumption (P48, IEC 61938) .................................................... 3.2 mA
Matching connector ................................................................................................... XLR3F
Weight .................................................................................................................. approx. 80 g
Diameter .......................................................................................................................... 22 mm
Length ............................................................................................................................ 107 mm

Technical Data

KM 184

KM 183

KM 185

measured in free-field conditions (IEC 60268-4)

1)

according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS

2)

measured as equivalent el. input signal

Advertising