Speed, Nmea out, Speed filter – Navman 4433 User Manual

Page 13: 7 setup > comms, Nmea data, Navbus, Navbus group, 8 setup > calibrate

Advertising
background image

Press MENU once or more until the Setup
menu is displayed, then select Calibrate:

The fuel options
can be calibrated
only when the
optional single
or twin engine
kit is installed on
petrol/gasoline
engines.

Speed*

Calibration may be required because different
hull shapes have different flow characteristics.

Obtain an accurate measurement of the boat’s
speed from a GPS receiver; or by following
another boat travelling at a known speed; or
by making a timed run over a known distance.

Use this feature when the FISH 4432/4433
is connected to other Navman instruments
through NavBus or any compatible NMEA
instrument.

Press MENU once or more until the Setup
menu is displayed, then select Comms:

NMEA Out

NMEA is generally used with third party
instruments. Select to transmit NMEA
sentences (see Appendix A - Specifications).

Note: for accurate calibration:

The speed from a GPS receiver should be
greater than 5 knots.

The speed from another paddlewheel
transducer should be between 5 and 20
knots.

Best results are achieved in calm conditions
where there is minimal current (best at high
or low tide).

Use the cursor keys to display the speed readout
box, then increase or decrease the readout to
match the independent speed value.

Speed Filter*

Increase this setting to stabilise an erratic
speed reading. Decrease to improve reading
responsiveness. The speed filter can be set
from 0 to 30 seconds.

* only available on 4433

3-7 Setup > Comms

(4433 only)

NMEA data

Use this to specify which NMEA sentences will
be transmitted (see Appendix A - Specifications
and section 5-7 Data display, for information
about how to display NMEA data).

NavBus

NavBus is the preferred method for connecting
the FISH 4433 to other Navman instruments.
Select if the instruments are connected using
NavBus.

NavBus Group

Use this when a group of Navman instruments
are connected together using NavBus, to
specify a group of instruments for backlighting,
if required. Then, if the backlight setting on one
instrument in the group is adjusted, the other
instruments change automatically. Otherwise,
select 0.

3-8 Setup > Calibrate

Fuel

Temperature

Select from:

Select either:

Litres

°F

(Fahrenheit)

• USGal (US gallons)

• °C (Celsius)

• ImpGal (Imperial Gallons)

FISH 4432/4433 Installation and Operation Manual

15

NAVMAN

Advertising
This manual is related to the following products: