Safety instructions – Nexgrill 720-0008-T User Manual

Page 4

Advertising
background image

Safety Instructions




Pipe sealing compound or pipe thread tape of the
type resistant to the action of natural gas must be
used on all male pipe threads when making the
connection.

3


Disconnect your gas grill from fuel source when
the gas supply is being tested at high pressures.
This appliance and its individual shut off valve
must be disconnected from the gas supply piping
system during any pressure testing of that
system at pressure in excess of 1/2 psi(3.5kpa)






Turn off your gas grill when the gas supply is
being tested at low pressure. This appliance
must be isolated from the gas supply piping
system by closing its individual manual shut off
valve during any pressure testing of the gas
supply piping system at pressures equal or less
than1/2 psi(3.5kpa)







WARNING: Gas valves are preset at factory to
operate on LP or nature gas. If you wish to
convert, be sure to contact your grill dealer
FIRST!




S

S

A

A

F

F

E

E

T

T

Y

Y

!

!

BEWARE

OF

SPIDERS

CAUTION:BURNER TUBES MUST B
INSPECTED AND CLEANED BEFOR
FIRST USE

spiders and small insects Occasionally spin

webs or make nests in the burner tubes

during warehousing and transit. These

webs can lead to a gas flow obstruction,

which could result in a fire in and around

the burner tubes. This type of fire is known

as “FLASH-BACK” and can cause serious

damage to your grill and create an unsafe

operating condition for the use. Although

an obstructed burner tube is not the only

cause of “FLASH-BACK” it is the most

common cause and frequent inspection and

cleaning of the burner tubes in necessary.

NATURAL GAS SAFETY(FOR natural
gas model)


Your natural gas grill is designed to operate on 7’’
water column residential (1/4 psi or 1.75 kpa)
regulate at the residential meter, Check with your
gas utility for local gas pressure and with your
local municipality for building code requirements.
If your residential gas utility line pressure has not
been regulated to 7’’ W.C. contact your local gas
utility or gas grill dealer for professional
assistance.









Check with your gas utility or with local building
codes for instructions to install gas supply line, or
call a licensed and knowledgeable installer.



It is recommended that an “ON-OFF” shut off
valve be installed at the gas supply source;
outdoors after gas line piping exits outside wall
and before quick-disconnect or before gas line
piping enters ground indoors in the branch fuel
line in an accessible location near the supply line.