3-5 Setup > Logs

Press MENU twice to display the Setup menu,
then select Logs:

The values can be changed independently of
each other. These log values are saved when the
unit is turned off.

Reset trip dist (Explorer 438 only)

This resets the trip distance to zero.

Reset total dist (Explorer 438 only)

This option resets the total distance to zero.

Reset engine hours

Use this option to reset the engine hours to zero.
This can be useful after an engine service or to
count the engine hours between service intervals.

c

Alarm Beeper Alarm condition is

Name Cycle

met when the:

Too

1

/

5

sec depth is less than

shallow

the

alarm

trigger

value

Too

1

/

2

sec depth is greater than

deep

the

alarm

trigger

value

Fish

1 short echo matches the fish

beep

profile selected by

fish

filter

Temp.

1

/

2

sec temperature equals

the

alarm

trigger

value

Temp.

1

/

2

sec rate of change of

rate

temperature

equals

the

alarm

trigger

value

Low

1

/

2

sec battery voltage is

battery

less

than

the

alarm

trigger

value

Low

1

/

2

sec fuel remaining equals

fuel

the

alarm

trigger

value.

3-6 Setup > Alarms

Press MENU twice to display the Setup menu,
then select Alarms:

Trigger settings can be defined to suit the boat
and individual preferences as follows:

Alarms can be set (enabled) to automatically detect
certain conditions, such as the water being too
shallow. Alarms that are enabled are shown as black
icons in the Alarm status box on the sonar displays.

When an enabled alarm is triggered, the beeper
sounds, an alarm message is displayed and the
alarm status icon is shown in red.

Press or MENU to acknowledge the alarm, stop
the beeper and close the alarm window. This
does not disable the alarm.

Alarms automatically re-enable

The Too shallow, Too Deep and Low
battery alarms automatically re-enable when
the value moves outside the alarm trigger setting.

The Temperature alarm automatically
re-enables when the temperature is more than
0.45°F (0.25°C) above or below the alarm trigger
setting.

The Temperature rate alarm automatically
re-enables when the rate of temperature change
falls below the trigger setting by more than 0.2°F
(0.1°C) per minute.

Flashing Light and/or External

Beeper (Explorer 438 only)

If a secondary alarm indicator is required, a flashing
light and/or external beeper can be installed. These
can be positioned anywhere suitable on the boat.
See section 6-4 Wiring options.