Total Number of Zones in Area 1

(Appears for New Panel Only)

Press the

A

button and then directly enter the total number of zones to be

programmed for Area 1. Valid entries are from 01 to 32. Directly enter the total
number of zones, including leading zeros. Use number buttons

1

through

9

. NOTE: Press the

0

button for a zero. The system is based on

groups of 4 zones each (after the first 8 zones), and will automatically round up
to the next group of 4. For example, if you enter 18, it will automatically

convert this to 20 zones. Press

J

to save. Press NEXT (

E

) button to

proceed. NOTE: If you are programming a 2 Area system, enter the total number of zones required for Areas 1 & 2. The
Direct Address Program Mode can then be used to remove zones from Area 1 and place them in Area 2. See Zone
Options. If Programming a Wireless Only system, or using wireless only on Zones 9-32, enter the total number of zones
in system. Enter the transmitter points in the RF Transmitter section of the Easy Menu Driven Programming Mode.

Panel Zone Doubling?

(Appears for New Panel Only) (GEM-P1632 only)

Press the

A

button. If the total number of zones in Area 1 entered was 16

or greater, press YES (

E

) to effectively double the capacity of the control

panel's hard wired zones from 8 to 16. The 16 zones will no longer be EOL
zones, but will be designated for Normally Closed devices only. The terminal
for Zone 1 will now support Zones 1 and 9 with the use of the supplied EZ
Zone Doubling

TM

resistors, E & Z supplied. (Refer to Wiring Diagram and

Installation Instructions). If Panel Zone doubling is not desired, press NO
(

E

). NOTE: Answer NO for GEM-P816

Fire Zones in Area 1

(Appears for New Panel Only) Press the

A

button and then directly enter the zone number of any zones which are to be
used as Fire Zones (both 2-wire, 4-wire or wireless). Valid entries are from 01
to 32. Directly enter each zone number, including leading zeros, and press

J

to save, and then repeat for any additional zone(s). Press NEXT (

E

)

button to proceed.

2-Wire Fire Zones in Area 1

(Appears for New Panel Only) Press the

A

button and then directly enter the zone number of any Fire Zones (from

previous question) which are to be used with 2-wire smoke detectors. The
only valid entries are 07 and 08. Directly enter each zone number, including

leading zeros. Press

J

to save and then repeat for any additional zone(s).

NOTE: Only zones which have been designated as Fire Zones may be pro-
grammed as 2 Wire Fire zones. Press NEXT (

E

) button to proceed.

NOTE: JP3 must be set to “2-WF” position for 2-wire fire zones for zones 7
and 8 (refer to Installation Instructions).

Report all Zones to Central Station?

(Appears for New Panel Only)

Press YES (

E

) button for all zones to report to central station; press NO

(

F

) button for no zones to report (LOCAL SYSTEM).

(Direct Entry)

01

INTERIOR

BYPASS

FIRE/TBL

SYS TBL

CHIME

INTERIOR

BYPASS

SYS TBL

CHIME

FIRE/TBL

(Press YES or NO)

03

INTERIOR

BYPASS

FIRE/TBL

SYS TBL

CHIME

INTERIOR

BYPASS

SYS TBL

CHIME

FIRE/TBL

(Press YES or NO)

04

INTERIOR

BYPASS

FIRE/TBL

SYS TBL

CHIME

INTERIOR

BYPASS

SYS TBL

CHIME

FIRE/TBL

(Press YES or NO)

05

INTERIOR

BYPASS

FIRE/TBL

SYS TBL

CHIME

INTERIOR

BYPASS

SYS TBL

CHIME

FIRE/TBL

Programming the GEM-P816 & GEM-P1632

R

COMPUTERIZED SECURITY SYSTEM

ARMED

STATUS

SYSTEM ARMED

01/01/97 12:00AM

1 2
4

3

5 6

7 8 9 0

A
B
C

D

E
F
G

NEXT/YES

PRIOR/NO

AREA

GEMINI

ENT A1

(Yes or No)

06

INTERIOR

BYPASS

FIRE/TBL

SYS TBL

CHIME

INTERIOR

BYPASS

SYS TBL

CHIME

FIRE/TBL