Shoot-thru-hull installation – New Transducers 250C User Manual

Page 15

Advertising
background image

G

ETTING

S

TARTED

>

I

NSTALLATION

Fishfinder 250/250C Owner’s Manual

11

Shoot-Thru-Hull Installation

To avoid drilling a hole to mount a thru-hull transducer, a transducer

may be secured with epoxy inside a boat (“shoot-thru-hull”

installation). This type of installation can reduce noise and allow you

to use a higher gain setting. For a transducer to be mounted inside

the hull (shoot-thru, not thru-hull), the boat must be fiberglass,

with no core. If you are unsure of your boat type, contact the

manufacturer. Professional installation may be necessary. Always

wear a dust mask and safety goggles when installing.
Some transducers are specifically designed to be mounted inside a

fiberglass hull. The standard plastic transom mount transducer can

also be mounted in this fashion using the following method. If using

a temperature sensing transducer, the temperature displayed reflects

the hull temperature.
When choosing a location for the transducer, consider the following

conditions:

• The location has to be solid fiberglass, devoid of any air

bubbles, laminates, fillers, or dead air space.

• The location needs to be in an area of clean water at all

speeds.

• The location must not be over any strakes or behind any

obstruction on the hull that would create turbulence at speed.

NOTE: Many modern hulls have a prelocated pocket for

shoot-thru-hull transducer installation. If you are unsure if your

hull is equipped with a pre-located pocket, contact your hull

manufacturer.

To test the location:

1. Fabricate a test device from a section of PVC pipe or a can,

as shown below.

2. Temporarily seal the test device to the hull with caulking or

RTV sealer, and fill with water or light mineral oil.

3. Place the transducer in the liquid, pointed directly at

the bottom. Weight it down. Set the unit for optimum

performance. If the sonar performance is significantly

degraded, find and test another location.

Testing the Location

Strip Caulk

or RTV Sealer

Hull

PVC Pipe

or a Can

Weight transducer

to hold it in place

Fill pipe or can

with water or a

light mineral oil

Advertising
This manual is related to the following products:

250