Nexstar SynScan User Manual

Page 12

Advertising
background image

PEC Training

1.

Perform the accurate

method (see the

manual).

2. Slew or manually point the telescope to a star with smaller DEC coordinate. This object will be

used as the guide star.
Activate Sidereal Tracking from the Setup Menu (see Setup Functions). Once the tracking has
started, press ESC to go back to the Setup Menu.

4. Rotate the reticle eyepiece until one set of the lines becomes parallel to (or matches) the R.A.

movement of the telescope (see step

2 to 4 of the Cone Error Calibration for more information on

how this is done.)

5. Move the guide star back at the center of the eyepiece view using the direction keys.
6. On the hand control, select PEC Training in the Utility Functions and press ENTER.

Utility Functions can be easily accessed by pressing the UTILITY quick reference

on

the keypad.

7. Select the R.A. guide speed for the PEC training.
8. The

hand control will display the current time once the guide speed is selected,

indicating that the recording has begun.

9. Using the LEFT or RIGHT direction key only, move the telescope so the guide star remains at

the center of the eyepiece view

s). Repeat whenever necessary.

The Guide star drifts

away from the center

Adjust the telescope to move the

guide star back to the center

For 8 minutes (10 minutes and 30 seconds for

the EQ6

hand control

records the manual guiding actions in order to characterize the periodic errors. Pressing ESC

will stop the recording immediately and exit from the PEC training function.

Guiding actions are recorded

the PEC training is stopped midway.

this case, the

tracking will not be accurate until a full cycle of the PEC training is performed.

11. The

will beep and display "Record completed" when the training time is up. Press

any key to exit from the PEC training.

Play back the PEC record

PEC tracking can be activated under the Setup Menu or pressing the SETUP quick reference

on the

keypad when needed. In the Setup Menu, choose Set Tracking, then

SynScan'" will play back

the corrections you made during the PEC training cycle and start tracking with periodic error compensated.

The

will continue to track in the

mode

another tracking

mode is selected. If the power is turned off while the

is under the

mode, the hand control loses synchronization with the

R.A.

worm gear and the PEC

Training will have to be performed again when the power is turned back on. To avoid this,

be sure to return the telescope to its home position by selecting

PARK

under the

before turning off the power.

Advertising