Connections – Niles Audio A4.6Ci User Manual

Page 39

Advertising
background image

TERMINATING FOUR-PAIR TWISTED CABLE
The Solo

™

and Select

™

Master Keypad Modules, the expander, and the A4.6Ci’s system-expansion connections

require a four-pair twisted cable with a one-to-one wiring configuration. To maintain consistency throughout
all Intellipad

®

Ci installations, we recommend the color-coding pattern described in Figure 31. However, you

may follow the color-coding pattern of your choice, as long as it is consistent throughout the system.

39

CONNECTIONS

1 2 3 4

Pair 2

Pair 1

T568A

Pair 3

Pair 4

5 6 7 8

1

= Green/White

2

= Green

3

= Orange/White

4

= Blue

5

= Blue/White

6

= Orange

7

= Brown/White

8

= Brown

Figure 31

Solo

™

Master

Keypad Module

Numeric

™

Accessory

Keypad Module

RJ-45 Connector for
connection to Master
Keypad Module

RJ-45 Connector
for connection to
Numeric

™

Accessory

Keypad Module

RJ-45 Connector
for connection to
IR Sensors

RJ-45 Connector for

connection to

the ZR-4630

Included

Jumper Cable

IR SENSOR

INPUT

OUTPUT

SYSTEM

ACCESSORY

KEYPADS

Figure 32

Figure 33

CONNECTING
NUMERIC

™

KEYPADS

Each Solo

™

and Select

™

Master Keypad

Module can be mated with one
optional Numeric

™

Accessory Keypad

Module using an included jumper
cable (see Figure 33).

CONNECTING THE SOLO

™

AND SELECT

™

MASTER KEYPADS TO

THE HOME RUN OF FOUR-PAIR TWISTED CABLE
The home run of four-pair twisted cable is terminated with a male
RJ-45 connector and plugged into the rear-panel jack labeled SYS-
TEM on the Solo

™

and Select

™

Master Keypad Module (see Figure 32).

Advertising