SPECIFICaTION

GS 100

GS 200

GS 300

GS 400

GS 500

GS 600

Capacity: lbs/hr

25-105

25-210

25-315

25-420

25-525

25-630

Capacity: kg/hr

11-47

11-95

11-143

11-191

11-238

11-286

Input BTU/hr max

140,000

280,000

420,000

560,000

700,000

840,000

Input kJ/hr max

41

82

124

165

206

247

Flue Emissions

Low CO (<10ppm) and NOx (<40ppm)

Unit rated Amps

4

6

8

10

12

14

Voltage/Phase

120V/1

120V/1

120V/1

120V/1

120V/1

120V/1

Unit rated Amps

2

3

4

5

6

7

Voltage/Phase

208-240/1

208-240/1

208-240/1

208-240/1

208-240/1

208-240/1

technical data

INSTaLLaTION FEaTuRES & REquIREMENTS

Single point cabinet door fastening for easy removal.

Choice of venting comes standard allowing greater installation flexibility,
B or BH venting.

Cabinet and insulation allows mounting to combustible surfaces for
minimum space requirement.

Exclusive full size cleanout port for fast and easy servicing.

Floor stand optional for GS indoor units.

All service connections exterior to the humidifier ready for field
connections.

120, 208-240V single phase power supply.

Steam outlet configuration ready for duct distributor, remote mounted
blower pack or Short absorption manifold connection.