To deactivate gating choose gating value zero.
NOTE: The gating distance can only be increased. To
exit the gating selection cycle without setting any gating
distance click through full gating range with M button or
hold M button for 2 seconds.
Gating feature helps measuring remote targets in
unfavourable atmospheric and environmental conditions
by eliminating reflections from snowflakes, raindrops,
industrial wires, tree branches, etc. At the same time, if
gating distance is set incorrectly, you can remove the
desirable object from measurement range.
5.10 Data Recall mode
In Data Recall mode results of the last 10 measurements
can be displayed.
Measurement results are saved in on-board memory in
sets depending on the parameters set for measuring, for
instance, if only distance is measured - the set will consist
of one number, if distance and speed are measured – the
set will consist of two numbers.
To enter Data Recall mode select rEc from the main
menu. First measurement set number (display name: rEc
1) will start flashing.
Pressing M button moves the unit along the list of
measurement set numbers and measurement results: