NI PCI-8254R User Manual

Figure 2-5. Connecting isolated input to a sourcing output device

Wiring an Isolated Output to an External Load

The digital output circuit sources current to external loads, as shown in
Figure 2-6.

Caution

Do not draw more than 100 mA from 24 V or 30 V isolated outputs. Do not draw

more than 50 mA from 5 V isolated outputs.

Figure 2-6. Digital output sources current to external loads

Vcc

Sourcing

Output
Device

V

Current

Limiter

C

NI 8254R

Input

Digital Output

V

C

Vcc

NI 8254R

Load