BLOWER INSTALLATION

4. Remove the 2 screws from the top outer edge of the rear
stove panel. The housing is mounted using these two
holes, as well as two other holes located in the rear panel.

5. Mount and secure the blower housing using 4 screws.
Ensure that the on/off switch wires pass through the appro-
priate slot located on either side of the blower housing.

6. Remove the 2 screws from the side of the blower housing
that you want the switch to be located on and re-secure the
on/off switch.

1. Ensure that the access cover plate has been installed.

2. Remove the on/off switch bracket and the cover plate
below it. The cover plate may now be discarded.

3. Decide which side of the blower housing you prefer the
on/off switch to be located on.

FIGURE 11

Because the blower is thermally activated, when
turned on, it will automatically start approximately
15-30 minutes after lighting the stove and will run
for approximately 30-45 minutes after the stove has
been turned off. Use of the fan increases the out-
put of heat.

Drywall dust will penetrate into the blower bear-
ings, causing irreparable damage. Care must be
taken to prevent drywall dust from coming into
contact with the blower or its compartment. Any
damage resulting from this condition is not cov-
ered by the warranty policy.

FIGURE 10

REMOVED SCREWS

SLOT

ACCESS PLATE

FIGURE 9

COVER PLATE

ON/OFF SWITCH BRACKET