Warnings and call out output, Warnings and their appropriate countermeasures – Nikon DX-TL4516E User Manual

Page 36

Advertising
background image

36

Warnings and their appropriate countermeasures

#1 Options in the CALL OUT output column:
• Selectable: Selects to output CALL OUT signal or not on the menu screen.
• Fixed: Outputs CALL OUT signal from the CALL OUT terminal regardless of the menu setting.
• None: Does not output CALL OUT signal, but displays a warning on the screen.

The warning display appears when the HELP button is pressed during “ALERT” is displayed on the screen. The contents

of last 16 warnings are stored and can be displayed. The contents older than them are cleared and output of CALL OUT is
cancelled. CALL OUT signal output can be stopped by pressing the E button or clicking “Clear Warning” while displaying
the warning display.

#2 :
#3 :
#4 :
#5 :
#6 :

#8 :

#7 :

Warning Display

CALL OUT

output

#1

Cancelling

the warning

Log number

Countermeasure

LOG1200

LOG1201

LOG1202

LOG7200

LOG1100#3
LOG4100#4
LOG1101#3
LOG4101#4
LOG1102

LOG3100

LOG7100

LOG3701#5
LOG7701#6
LOG4701#4

LOG3702#5
LOG7702#6
LOG4702#4

LOG3703#5
LOG7703#6
LOG4703#4

LOG3704#5

LOG7704#6

Selectable

Selectable
None
Selectable
None
Selectable

None

Selectable

None

None

None

None

The remaining capacity of Normal Area
in Main device has become less than **%.#2
The remaining capacity of Alarm Area
in Main device has become less than **%.#2
The remaining capacity of LPA Area
in Main device has become less than **%.#2
The remaining capacity of Copy 2 disk
has become less than **%.#2
The remaining capacity of Normal Area
in Main device has become 0%.
The remaining capacity of Alarm Area
in Main device has become 0%.
The remaining capacity of LPA Area
in Main device has become 0%.
The remaining capacity of disc in Copy 1
drive has become 0%.
The remaining capacity of disc in Copy 2
drive has become 0%.
Copy data size error.

Check the range of copy data or the disk space
of copy media.
Copy media error.

Cannot copy the data.
Check the copy device.

No disk.

The drive has no disk or wrong type of disk.
Put a proper disk into the drive.
The remaining capacity of disc in Copy 1
drive has become 0%.
Put a new disk into the drive.
The remaining capacity of disc in Copy 2
drive has become 0%.
Put a new disk into the drive.

• Copy data as necessary.

• When the warning is cancelled,

the unit starts overwriting the
oldest data remaining in the
HDD.

• Copy data as necessary.

• Replace media if necessary.

• Set the copy/restore range again.
• Replace with new media.

• Check that media is in the

recording device. (If not, insert
the media.)

• Check whether that the write-protect

of the media is enabled. Is so,
cancel the protection.

• After turning off the power of the

peripheral recording device and
the unit, reboot in order of
peripheral recording device and
the unit.

• After turning off the power of the

peripheral recording device and
the unit, check a cable.

• Insert the disc.

• Replace the disc.

Click "Clear
Warning" or
press the E
button.

Click "Clear
Warning" or
press the E
button.

Click "Clear
Warning" or
press the E
button.
Click "Clear
Warning" or
press the E
button.
Click "Clear
Warning" or
press the E
button.

Click "Clear
Warning" or
press the E
button.
Click "Clear
Warning" or
press the E
button.

The value depends on the setting.
Log number for recording
Log number for restore
Log number for copy 1
Log number for copy 2

13 ,14 : Recording

23 ,24 : Playback

33 ,34 : Copy 1

43 ,44 : Restore

73 ,74 : Copy 2
(The following numbers are entered in )
00 : A (Internal)

01 : B (Internal)

10 to 25 : USB (External)

(The following numbers are entered in )
01 : CH 1 02 : CH 2 03 : CH 3 04 : CH 4
05 : CH 5 06 : CH 6 07 : CH 7 08 : CH 8
09 : CH 9 10 : CH 10 11 : CH 11 12 : CH 12

13 : CH 13 14 : CH 14 15 : CH 15 16 : CH 16