Connecting signals – National Instruments SHC68-H1X38 User Manual

Page 4

Advertising
background image

Digital Flying Lead Cable User Guide

4

ni.com

Figure 2. Detailed Parts Locator Diagram for the Lead Pairs

Connecting Signals

Each DIO, PFI, and clock channel of the NI digital waveform
generator/analyzer connects to a corresponding pair of leads on the
NI SHC68-H1X38 cable.

The NI SHC68-H1X38 cable is separated into two bundles of 19 channels,
and each channel is split into a pair of leads for connecting the signal and
its associated ground. Table 1 describes the channels and shows how they
are grouped by bundle.

1

0.25 in. diameter 0.1 in. pitch
compatible receptacles

2

Strain-relief and label

3

Microcoaxial wire

4

Ground

Table 1. NI Digital Waveform Generator/Analyzer Signal Descriptions

Channel

Signal Description

Bundle

DIO <0..31>

Bidirectional digital data channels 0
through 31. Refer to the documentation
for your NI digital waveform
generator/analyzer for information about
the number of available DIO channels on
your device. DIO <20..31> may not
apply to your device.

DIO<0..15>: Bundle A

DIO<16..31>: Bundle B

STROBE / PFI 5

For devices that have a STROBE
channel, this signal is the external
Sample clock source for dynamic
acquisition. Otherwise, this is
programmable functional interface
(PFI) 5.

Bundle A

1

2

3

4