Electrical Characteristics

(Continued)

Over recommended operating supply and temperature ranges unless otherwise specified.

Symbol

Parameter

Conditions

Min

Typ

Max

Units

RECEIVER SUPPLY CURRENT

ICCRW

Receiver Supply Current

Worst Case

(Figures 2, 4)

C

L

= 8 pF,

Worst Case

Pattern

Default Register

Settings

f = 8 MHz

65

130

mA

f = 135 MHz

375

550

mA

ICCRG

Receiver Supply Current

Incremental Test Pattern

(Figures 3, 4)

C

L

= 8 pF,

Worst Case

Pattern

Default Register

Settings

f = 8 MHz

55

120

mA

f = 135 MHz

245

400

mA

ICCRZ

Receiver Supply Current

Power Down

PDWNB = Low

Receiver Outputs stay low

during Powerdown mode.

Default Register Settings

2

mA

Note 1: “Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed. They are not meant to imply that the device
should be operated at these limits. The tables of “Electrical Characteristics” specify conditions for device operation.

Note 2: Typical values are given for V

DD

= 3.3V and T

A

= +25˚C.

Note 3: Current into device pins is defined as positive. Current out of device pins is defined as negative. Voltages are referenced to ground unless otherwise
specified.

Note 4: The worst case test pattern produces a maximum toggling of digital circuits, LVDS I/O and LVCMOS/LVTTL I/O.

Note 5: The incremental test pattern tests device power consumption for a “typical” LCD display pattern.

Note 6: Figures 2, 3 show a falling edge data strobe (RCLK OUT).