3. ensure that there is only one input signal connected

to channel 1 of the amplifier - channel 2 input must be
vacant

4. switch the amplifier to bridged mono (back panel

switch)

5. turn the gain down and turn on the amp

6. verify operation at low gain, and then increase power

to desired level, ensuring that the gain controls on
each channel are set equally.

IMPORTANT: NEVER SWITCH BETWEEN
STEREO AND BRIDGED MONO OPERATION
WHEN THE AMPLIFIER POWER IS ON.
11. Limiter On / Off Switch
In cases where a dedicated compressor / limit unit
precedes the SA5500, some users may seek to disable
the on board limiting. Sliding the switch to the off position
removes the limiting from both channels of the amplifier.