Adjustments, Blower replacement installation, Pilot burner adjustment venturi adjustment – Napoleon Fireplaces GDI-30N User Manual

Page 10

Advertising
background image

10

W415-0384 / D / 09.13.05

FIGURE 9

BLOWER ACCESS COVER

1. Turn off the electri-
cal power and the gas
supply to the fireplace
insert.
2. Open the glass door
and remove the logs
and fibre bricks, if in-

stalled.

3. Remove the blower access cover held on with 4 screws.

4. Remove the blower mounting plate with the blower
attached.
NOTE: Check the blower gasket for damage. Replace if

shutter will cause a more yellow flame, but can lead to
carboning. Opening the air shutter will cause a more blue
flame, but can cause flame lifting from the burner ports.

FIGURE 12

Air shutter adjustment must only be done by a qualified

gas installer!

FIGURE 14

The flame may not appear yellow immediately; allow 15 to
30 minutes for the final flame colour to be established.

ADJUSTMENTS

PILOT BURNER ADJUSTMENT

VENTURI ADJUSTMENT

FIGURE 13

P

I

PI

PILOT SCREW

LOT

N O

L

O

T

H I

LO

FF O

damaged.
5.
Disconnect the two blower wires. Remove the blower
from the mounting plate and replace.
For thermodisc replacement: Remove the mounting
bracket secured to the underside of the burner base. Re-
move the thermodisc from the bracket and replace.
6. Reconnect the two wires. Re-install the blower gasket.
Reattach the blower mounting plate and blower access
cover. Replace the logs. Close the fire viewing door.
7. Turn the gas supply and electricity back on.
Because the blower is thermally activated, when turned on,
it will automatically start approximately 5-15 minutes after
lighting the fireplace insert and will run for approximately
30-45 minutes after the fireplace insert has been turned
off. Use of the fan increases the output of heat.
Drywall dust will penetrate into the blower bearings caus-
ing irreparable damage and must be prevented from com-
ing into contact with the blower or its compartment. Any
damage resulting from this condition is not covered by the
warranty policy.

BLOWER REPLACEMENT INSTALLATION

FIGURE 11

THERMODISC / BRACKET ASSEMBLY

FIGURE 8

red

white

bla

ck

BLOWER ACCESS COVER REMOVED

MOUNTING

PLATE

FIGURE 10

Advertising
This manual is related to the following products: