PIPING DIAGRAM WITH UV-LIGHT

TO

ELECTRICAL

OUTLET

1

3

2

4

9 X
N570-0043 (8-32 X 3/4")

B

A

FROM WATERFALL

DRAIN TO BASIN

FROM THREE WAY

VALVE TO

WATERFALL

FROM BASIN TO

WATERFALL DRAIN

OVERFLOW

PROTECTION

PURGELINE

FROM WATER

SOURCE TO

FLOAT VALVE

B

A

TO DRAIN

FROM THREE WAY

VALVE TO WATERFALL

SADDLE VALVE

FLOW CONTROL

VALVE / PURGE

VALVE

INSTALLTHE SUPPLIED

HOSE CLAMPS ON EITHER

SIDE OF THE BASIN

SEDIMENT

FILTER

UV

LIGHT

Remove components from basin and assemble as shown. The fittings required are already attached to the filter and basin.

When using the optional UV light, the barbed elbow fitting on the “IN” side of the filter will need to be removed and threaded into the
elbow at the bottom of the UV light. Then connect the UV light directly to the sediment filter. Use teflon tape to seal these connec-
tions. Ensure that the supplied ground wire is connected from the grounding terminal on the UV light to either grounded copper
plumbing, or the ground in your electrical system. Use the supplied short piece of black tubing to run from the pump to the UV light.
Measure and cut the lines to the length necessary, push onto the barbed fittings and secure with the supplied hose clamps. Leak
test the waterfall before fully enclosing.