Mounting the hood body

• Before attaching the hood body, tighten the two screws Vr lo-

cated on the hood body mounting points.

• Hook the hood body onto the screws 12a.
• Fully tighten support screws 12a.
• Adjust screws Vr to level the hood body.

12a

Vr

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert the re-

ducer flange 9 on the hood body outlet.

• Fix the pipe in position using sufficient pipe clamps (not sup-

plied).

• Remove possible charcoal filters.

9

ш 120

ш 150

RECIRCULATION VERSION AIR OUTLET

• Insert the connection extension pieces laterally 14.1 in connec-

tion 15.

• Insert the Connector 15 into the Support bracket 7.3 and fix it

with a screw.

• Make sure that the outlet of the extension pieces 14.1 is hori-

zontally and vertically aligned with the chimney outlets.

• Connect the air outlet connection 15 to the hood body outlet

using either a flexible or rigid pipe ø 150 mm, the choice of
which is left to the installer.

• Ensure that the activated charcoal filters have been inserted.

ш 150

15

14.1

7.3