La b te st – Ricoh GX5050N User Manual

Page 9

Advertising
background image

© 2007 Buyers Laboratory Inc. WARNING: This material is copyrighted by Buyers Laboratory Inc. and is the sole property of Buyers Laboratory. Duplication of this proprietary report or excerpts from this report, in any man-

ner, whether printed or electronic (including, but not limited to, copying, faxing, scanning or use on a fax-back system), is illegal and strictly forbidden without written permission from Buyers Laboratory. Violators will be pros-

ecuted to the fullest extent of the law. To purchase reprints of any BLI reports or articles, contact BLI at (201) 488-0404. Buyers Laboratory Inc., 20 Railroad Avenue, Hackensack, NJ 07601. Contact us at [email protected].



LA

B

TE

ST

Ricoh Aficio GX5050N

Buyers LaBoratory

Lab TesT RepoRT

© 2007 Buyers Laboratory Inc. WARNING: This material is copyrighted by Buyers Laboratory Inc. and is the sole property of Buyers Laboratory. Duplication of this proprietary report or excerpts from this report, in any man-

ner, whether printed or electronic (including, but not limited to, copying, faxing, scanning or use on a fax-back system), is illegal and strictly forbidden without written permission from Buyers Laboratory. Violators will be pros-

ecuted to the fullest extent of the law. To purchase reprints of any BLI reports or articles, contact BLI at (201) 488-0404. Buyers Laboratory Inc., 20 Railroad Avenue, Hackensack, NJ 07601. Contact us at [email protected].



LA

B

TE

ST

Ricoh Aficio GX5050N

Buyers LaBoratory

Lab TesT RepoRT

readings are averaged for two separate drips. The sample is
allowed to dry for one hour before drip test is performed.
Two samples are tested, one at default quality and one at the
highest quality.

Average Colorant Transferred

Drip 1

Drip 2

Standard (default)

.000

.000

Black Highlighter Smearfastness:
The test measures the amount of colorant transferred from a
printed area to an unprinted area when briefly contacted by
two types of highlighters. Density readings are taken for each
type of highlighter before and after vertically crossing five
printed parallel horizontal bars to determine the amount of
black ink transferred. The sample is allowed to dry one hour
before testing. Two samples are tested (one at the default
quality and one at the highest quality setting).

Difference of Colorant Transferred

Alkaline

Acid

Standard (default)

0.02

0.02

This report has been reproduced with the written permission of Buyers Laboratory Inc. Any duplication of this report, in whole or part, in any form or manner,
without the written permission of Buyers Laboratory, is unlawful and violators will be prosecuted. © 2007 Buyers Laboratory Inc. To purchase reprints,

contact BLI at (201) 488-0404 (x17) or at [email protected].

Advertising