WIRING AT THE CONTROLLER

CAi System keypads are wired with CAT-5 wire. It is inexpen-
sive and color coded for ease of installation. Due to the
qualities of CAT-5 wire, when using it for keypad control
wire with the CAi-Series, it is recommended to use the fol-
lowing color code for maximum performance. NOTE: 250ft
run of wire maximum per keypad is recommended.

CAT-5

Type

Brown/White

Ground

Brown

IR Signal

Green

12VDC+

Orange/White

Source Select

Orange

Source Select

Green/White

Channel Select

Blue/White

Volume

Blue

Balance

CLEAN INSTALLATIONS

For clean installations, we recommend using RJ-45 jumpers
to run from the CAi controller to an RJ-45 Wall Plate then
running your keypads from the Wall Plate.

K

EYPAD

C

ONNECTIONS

A

T

C

ONTROLLER

K

EYPAD

P

ORTS

1

2

3

4

1 2 3 4 5 6 7 8

CAT-5 Cable

RJ-45 using T568A
Wiring Standard

• Each keypad connection on the back panel of the CAi-Series Master

Controller corresponds to the room / zone number chosen for your
speakers. Each zone operates independently, so it is very important to
connect the keypad to the correct zone keypad input.

• On List 4 (opposite) copy down the room name to the zone number

from List 3 on pg 6. NOTE: the keypad and the speakers in each room
must be hooked to the corresponding numbered zone.

List 4 – Room names should be written below.

Zone 1 _________________

Zone 2 _________________

Zone 3 _________________

Zone 4 _________________

Figure 9 – Connections with CAT-5 wire

Figure 10 – Connections with RJ-45 Wall Plate