Figure 12 vpp/p90 and test pin protection circuits, Figure 13p1 short connector – Renesas H8/3644 Series User Manual

Page 24

Advertising
background image

6. The flash memory functions of the H8/3644 series are not supported by the emulator. Therefore,

do not apply 12 V to Vpp/P90 and TEST pins. If 12 V is applied, the emulator will detect it as
the test mode. The Vpp/P90 and TEST pins have circuits for protection against 12-v application,
as shown in figure 12.

To E6000 emulator station

To E6000 emulator station

10 k

27 k

15 k

470

Zener voltage: Approx. 6.0 V

x 2

Vpp/P90 pin (P90 is an I/O port)

From user system

From user system

TEST pin

Figure 12 Vpp/P90 and TEST Pin Protection Circuits

7. The P1 short connector is used for testing. Do not remove the inserted jumper pin.

Figure 13 P1 Short Connector