INSTALLATION

Check the appliance is electrically safe when you have finished.

Secure the hob to the worktop using the brackets supplied.
The positioning of the bracket (and sleeve) is dependent on
the thickness of the worktop as shown in (Fig.5-4).

Note: Slide the optional sleeve onto the bracket if fitting to
thin work surfaces.

Locate the bracket to the slot on the hob base and then
tighten the retaining screw until it is locked to the worktop.

Electrical Connections

This appliance must be installed by a qualified electrician
to comply with the relevant Institute of Electrical
Engineers (I.E.E.) regulations and also the local electricity
supply company requirements.

WARNING: THIS APPLIANCE MUST BE EARTHED

Note: All external wiring must comply with the IEE
Regulations for the Electrical Equipment of Buildings.
Connection to the electrical supply can be made with either
a plug and socket, or be permanently wired via a double pole
switch.

The electrical cable to be fitted must be 250V high
temperature PVC (85°C), 2.5mm² minimum conductor size.

Connect the hob up as shown in Fig.5-5 and Fig.5-6.

IMPORTANT: The wires in the mains lead are coloured in
accordance with the following code:

Green and yellow:

Earth

Blue:

Neutral

Brown:

Live

Hob Check

Check each cooking zone in turn.

Customer Care

Please complete your contact details in the front of this
section. Please inform the user how to operate the hob and
hand over the instruction pack.
Thank you.

ArtNo.130-0008 - Electrical connections Induction hob

��

��

��

��

�����

��������

Fig.5-5

ArtNo.314-0010 Induction electrical label

2

4

3

5

1

2

4

3

5

1

L1

L2

N

L

N

400V 2N

230V

H05RR-F4x2.5

H05RR-F3x2.5

Fig.5-6

ArtNo.317-0012 - Hob fittings 1

�������

�������

���������

�����

������

�������

���

�������

���������

�����

���

�����

�����

Fig.5-4