Switching characteristics, Operating characteristics – Renesas HD74LV2GT66A User Manual

Page 5

Advertising
background image

HD74LV2GT66A

Rev.2.00, Oct.17.2003, page 5 of 9

Switching Characteristics

•

V

CC

= 3.3 ± 0.3 V

Ta = 25°C

Ta = –40 to 85°C

Item

Symbol

Min

Typ

Max

Min

Max

Unit

Test

Conditions

FROM

(Input)

TO

(Output)

—

1.5

6.0

—

10.0

C

L

= 15 pF

Propagation
delay time

t

PLH

t

PHL

—

4.0

9.0

—

12.0

ns

C

L

= 50 pF

IN/OUT
or OUT/IN

OUT/IN
or IN/OUT

—

4.0

11.0

—

15.0

C

L

= 15 pF

Enable time

t

ZH

t

ZL

—

6.0

18.0

—

22.0

ns

C

L

= 50 pF

C

IN/OUT
or OUT/IN

—

5.0

11.0

—

15.0

C

L

= 15 pF

Disable time

t

HZ

t

LZ

—

8.0

18.0

—

22.0

ns

C

L

= 50 pF

C

IN/OUT
or OUT/IN

•

V

CC

= 5.0 ± 0.5 V

Ta = 25°C

Ta = –40 to 85°C

Item

Symbol

Min

Typ

Max

Min

Max

Unit

Test

Conditions

FROM

(Input)

TO

(Output)

—

1.0

4.0

—

7.0

C

L

= 15 pF

Propagation
delay time

t

PLH

t

PHL

—

3.0

6.0

—

8.0

ns

C

L

= 50 pF

IN/OUT
or OUT/IN

OUT/IN
or IN/OUT

—

3.0

7.0

—

10.0

C

L

= 15 pF

Enable time

t

ZH

t

ZL

—

5.0

12.0

—

16.0

ns

C

L

= 50 pF

C

IN/OUT
or OUT/IN

—

4.0

7.0

—

10.0

C

L

= 15 pF

Disable time

t

HZ

t

LZ

—

6.0

12.0

—

16.0

ns

C

L

= 50 pF

C

IN/OUT
or OUT/IN

Operating Characteristics

•

C

L

= 50 pF

Ta = 25°C

Item

Symbol

V

CC

(V) Min

Typ

Max

Unit

Test Conditions

Power dissipation
capacitance

C

PD

5.0

—

4.0

—

pF

f = 10 MHz

Advertising