4 call signal option card installation – RTS SSA-424 User Manual

Page 17

Advertising
background image

SSA-424 U

SER

M

ANUAL

17

6 Set the 2W CHAN SEL switches to either OFF

position.

7 Input a 1kHz, -10dBu test signal at the 4-wire

audio input. Use either connector:

9-Pin Connector
Pin 7: Balanced Audio - input
Pin 8: Balanced Audio + input

RJ11 Connector
Pin 2: Balanced Audio + input
Pin 3: Balanced Audio - input

8 Adjust RV102 (System A) or RV202 (System B)

while watching the bottom display (TO2W). All of
the green displays should be lit and no amber
displays should be lit.

9 Remove the test signal. This completes the

adjustment.

4.4

C

ALL

S

IGNAL

O

PTION

C

ARD

I

NSTALLATION

Use these instructions to install a Call Signal Option
Card in an SSA-424 that was originally ordered
without it.

1 Disassemble the SSA-424 as previously de-

scribed.

2 Assemble the standoffs to the circuit board using

the supplied screws and lockwashers.

3 Connect the supplied power cable from J8 on the

option card to J303 on the main board of the
SSA-424.

4 Insert the connectors on the option card into the

connectors on the main board.

5 Use the remaining screws and lockwashers to

secure the standoffs to the main board.

6 Reassemble the SSA-424.

Figure 11. The Call Signal Option Card after installation in the
SSA-424.

Advertising