TOTAL POWER:

ZGL 683IT:

G20/G25 (2E+) 20/25

mbar = 9 kW

G30 (3+) 28-30 mbar =

654 g/h

G31 (3+) 37 mbar = 649g/

h

ZGL 643IT:

G20/G25 (2E+) 20/25

mbar = 8 kW

G30 (3+) 28-30 mbar =

567 g/h

G31 (3+) 37 mbar = 557

g/h

Electric supply:

230 V ~ 50 Hz

Category:

II2E+3+

Gas supply:

G20/G25 (2E+) 20/25

mbar

Appliance class:

3

By-pass diameters

Burner

Ø By-pass in 1/100 mm.

Auxiliary

28

Semi-rapid

32

Rapid

42

Triple Crown

56

Gas burners

BURNER

NORMAL

POWER

REDUCED

POWER

NORMAL POWER

NATURAL GAS

G20/G25 20/25 mbar

LPG (Butane/Propane) G30/G31

28-30/37 mbar

kW

kW

inj. 1/100

mm

G20

G25

inj. 1/100

mm

G30

G31

m³/h

m³/h

g/h

g/h

Auxiliary

burner

1,0

0,33

70

0,095

0,111

50

73

71

Semi-rap-

id burner

2,0

0,45

96

0,190

0,221

71

145

143

Rapid

burner

3,0 (nat.

gas)

2,8 (LPG)

0,75

119

0,286

0,332

86

204

200

Triple

Crown

burner

4,0

1,4

146

0,381

0,443

98

291

286

Environment concerns

The symbol on the product or on its packaging

indicates that this product may not be treated as

household waste. Instead it should be taken to the

appropriate collection point for the recycling of electrical

and electronic equipment. By ensuring this product is

disposed of correctly, you will help prevent potential

negative consequences for the environment and human

health, which could otherwise be caused by inappropriate

waste handling of this product. For more detailed

information about recycling of this product, please contact

your local council, your household waste disposal service