1 switch settings, Chapter 3. setting up – Renesas M30220T-PRB User Manual
Page 16

( 14 / 36 )
Chapter 3. Setting Up
With this product, it is necessary to set the following according to your application system.
• X
CIN
/X
COUT
pins for the target system
• Mounting the A-D conversion bypass capacitor
3.1 Switch Settings
It is necessary to set the switches of the FLX64-PRB for debugging according to the target system.
Figure 3.1 shows the positions of the switches of the FLX64-PRB, and Table 3.1 shows the switch
settings.
Figure 3.1 Positions of the switches and their factory-settings
Table 3.1 Switch settings of FLX64-PRB
Function
Switch setting
Switch No.
Selecting
X
CIN
JP1
Selecting
X
COUT
JP2
As this switch is not used for M30220T-PRB,
X
CIN
is always selected.
Used when X
COUT
is connected to
the target system
(Factory-setting)
Used when X
COUT
is not
connected to the target system
PORT
NC
PORT
NC