Renesas RJJ10J1643-0101 User Manual

Page 201

Advertising
background image

Rev.1.01 2007.02.16
RJJ10J1643-0101

199

__GetADCStatus

Synopsis

<Get the status of A/D converter>

Boolean __GetADCStatus(unsigned int *status)

status

Pointer to the buffer in which the register content indicating A/D converter

status is stored.

Description

Gets the status of a specified A/D converter.

The status of interrupt bit (when using the M16C or R8C) or the value of A/D end flag
(when using the H8/300H) is stored in the first low-order bit of *status. Furthermore,
the status of A/D conversion start flag is stored in the second low-order bit of *status.

When used in the M16C, the value of A/D conversion status register 0 is stored in the 8
high-order bits of *status.

[Configuration of *status]



Value of A/D conversion status
register 0 (for only the M16C; 0 for
the R8C and H8/300H)

Value of A/D conversion start flag (for only
the R8C; 0 for the M16C and H8/300H)

Return value

If A/D converter status was successfully acquired, RAPI_TRUE is returned; if failed,
RAPI_FALSE is returned.

Functionality

A/D converter

Reference

__ClearADCStatus

Program example

#include " rapi_ad_r8c_13.h"

void func( void )
{
unsigned int status;

/* Get status of A/D convertered */
__GetADCStatus( &status );
}

0

0

0

0

0

0

Value of interrupt
bit or A/D end flag