Installation, Log set installation, Conversion to lower btu rating – Regency Freestanding Gas Stove F39-LPG User Manual

Page 18

Advertising
background image

18

Regency

®

F39 Room Sealed Freestanding Gas Stove

LOG SET

INSTALLATION

Read the instructions below carefully and
refer to the diagrams. If logs are broken
do not use the unit until they are replaced.
Broken logs can interfere with the pilot
operation.

The gas log kit contains the following:

a) 02-65 Rear

Log

b) 02-56 Middle Left Log
c) 02-44 Front Left Log
d) 02-46 Left

Top

Log

e) 02-45 Front Right Log
f) 02-47 Center

Log

g) 02-48 Middle Right Log
h) Embers

902-151

i) Lava

902-154


Note: Install Optional Brick Panels prior to

installing logs.

Embers

Embers

The "02" refer numbers (i.e. 02-65) are

molded into the rear of each log.

1) Carefully remove the logs from the box and

unwrap them. The logs are fragile, handle
with care - do not force into position.

2) Sprinkle the embers on the left and right

sides of the fi rebox base.

INSTALLATION

CONVERSION TO LOWER BTU RATING

THIS CONVERSION MUST BE DONE BY AN AUTHORIZED GAS

FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!

NG Conversion Kit 730-920
Contains:
Qty. Part # Description
1 904-240 Burner Orifi ce #37 (NG)
1 918-034 Decal "Converted to 30,000 Btu"
1 918-033 Instruction Sheet

LPG Conversion Kit 730-922
Contains:
Qty. Part # Description
1 904-390 Burner Orifi ce #52 (LPG)
1 918-034 Decal "Converted to 30,000 Btu"
1 918-033 Instruction Sheet

Additional Piece (pkg. with unit:
1

Log Bracket Restrictor

1) Shut off the gas supply.

2) Open the front door. Carefully remove the

logs and lava rock.

3) Remove burner. See diagram below.

Burner Orifi ce

4) Unscrew the 2 Rear

Log Pins and move
to the front hole posi-
tion.


5) Remove Rear Log

Bracket and slide the
Log Bracket Restric-
tor between the Rear

Position the Log Bracket Restrictor between

the Rear Log Bracket and the burner.

6) Remove burner orifi ce with a 1/2" spanner

and discard.

7) Reinstall new burner orifi ce (NG stamped

#37 or LPG stamped #52) and tighten.

8) Reverse steps 3) and 2).

9) Adjust Flue restrictor setting: To set the Flue

restriction as indicated in the diagram, simply
loosen the screws and push the fl ue restric-
tor plate to the correct position. Tighten the
screws.

Unit Btu/h

Restrictor

Opening

F39 40

Mj/h

A

45mm

31

Mj/h

B

35mm

Note: Use a magnetic

type screwdriver if

possible.

Log Bracket and the burner, secure with the
2 screws.

Flue Restrictor set-

ting at High Btu/h

Flue Restrictor set-

ting at Low Btu/h

10) Attach the label "This unit has been con-

verted to..." on top of the data badge over
the higher Btu information.

11) Check for gas leaks.

12) Check inlet and outlet pressures.

13) Check operation of fl ame control. Check for

proper fl ame appearance on logs.

Advertising