8.3 CAN bus (UART B) protocol

The RDR-3100 provides a second port to receive the speed and reverse message from the
input source. If the module receives the following input message then the DR module will
stop reading the speed and reverse message from MCU.
The communication settings:
Baud rate: 38400, n, 8, 1
Update rate: 1 Hz

8.3.1 Speed, Reverse status input Message

This sentence contains the speed and reverse information that read from CAN bus.
The protocol is illustrated as the following:
Item Field

Description

1

$

Beginning of the sentence

2 PSRF121

Message

Header

3 Speed

4

Reverse

High-normal / Low - activated

5 *CC<CR><LF>


Example:

Example: 
$PSRF121, 100, 1*25 
Speed = 100 * scaled meter/second 
Reverse isn’t activated 
Checksum = 25 