Features of the rhfe-431wta units safety devices – Rinnai RHFE-431WTA User Manual

Page 3

Advertising
background image

FEATURES OF THE RHFE-431WTA UNITS

SAFETY DEVICES

– 1 –

◆ Clean Heating Forced Flue Type

◆ Easy Operation One-Touch Ignition

◆ Sensible Temperature Control Feature

◆ Comfortable Room Temperature Control and Display

◆ Warm Air Outlet at Floor Level (Keeps Your Feet Warm)

◆ Child Safety Function Lock

◆ Room Temperature Setting Memory

◆ Dirty Air Filter Indicator Lamp

◆ Energy-Saving Economy Setting

◆ Humidifier Tray

◆ Air Flow Directional Louvers

◆ Direct Vent Easily Installed

◆ Proportional Heating Variable Capacity

◆ Hush! Quiet Operation

◆ Modern Design Minimizes Floor Space Requirements

◆ Failure Message Display

◆ Timer Override Mode

Spark Safety Device:

Automatically shuts unit down when there is an abnormal spark at time
of ignition.

Flame Failure Device: Activated when burner flame fails. This prevents raw gas from being

released.

Overheat Switch:

This device automatically cuts the gas off if the heater exceeds a
predetermined temperature. This is normally caused by an
obstruction in front of the louvers, or a blocked fan filter.

Fusible Links:

Backs up the overheat switch. If the fusible link cuts the unit off, a
service call by an authorized person is required to replace the link.

Overcurrent Prevention Device:

This is a 3 amp. glass fuse found on P.C. board. Design

to shut unit down in case of overcurrent. If fuse blows all
indicator lamps will be "OFF".

Power Outage Safety Device:

This safety device cuts off gas passage and stops

operation.